3.18

Top & Bottom End Caps

The top & bottom end panels are where all connections are made to the TI-CMXDL. The
diagram above shows the layout and description of the connectors:

Transducer Connectors

Refer to Diagram: The transducer connectors, and battery cover/probe zero disk are located
on the TI-CMXDL’s top end cap. The transducer connectors are of type Lemo “00”.

NOTE: There is no polarity associated with connecting the transducer to the TI-CMXDL.

Probe Zero Disk & Battery Cover

Refer to Diagram: The Battery cover is the large round disk shown in the diagram. Note:
This same disk is also used as a probe zero disk. Simply remove the cover when replacing
the batteries (3 AA cells). When performing a manual probe zero function, simply place the
transducer on disk making firm contact.

IMPORTANT: Be sure to follow the polarity labels located on the back label of the
TI-CMXDL.

NOTE: Rechargeable batteries can be used, however they must be recharged outside of the
unit in a stand alone battery charger.

RS-232 Connector

Refer to Diagram: The RS-232 connector, located on the bottom end cap, is a 2 pin
female Lemo connector. It is designed to connect directly from the TI-CMXDL to a
standard AT serial port on a PC. The cable supplied with the TI-CMXDL is a Lemo to

9 pin serial cable. Note: This connector is also used to upgrade the TI-CMXDL with the

latest version of firmware.

USB Serial to USB Converter Cable

A converter cable can be attached to the 9 pin serial cable in needed (part no. N-402-0510).

-18-

4. Press the ENTER key to display the new Grid or Seq Edit Box.

5. Use the UP and DOWN arrow keys to scroll through the new Grid or Seq List Items

until NAME is highlighted.

6. Press the ENTER key to activate the Alpha Edit Box.

7. Use the UP, DOWN, LEFT, & RIGHT arrow keys to

highlight the appropriate alpha characters.

8. Press the ENTER key to select a character and

advance to the next field of the Grid or Seq Name.

9. Use the CLR key to backspace if necessary.

10. Repeat steps 6 – 9 until the Grid or Seq Name

(File Name) is completed.

11. Press the OK key to save the Grid or Seq Name and return to the Grid or Seq List

Items menu, or ESC to cancel entering the Grid or Seq Name (File Name).

Creating A Note

Grid/Seq Log Note: Can contain a
combination of up to 20 numeric,
alpha, or special characters listed in
the first section of this chapter.

1. Assuming the Grid or Seq List

Items are displayed, use the UP
and DOWN arrow keys to scroll
through the new Grid or Seq List
Items until NOTE is highlighted.

2. Press the ENTER key to activate the Alpha Edit Box.

3. Use the UP, DOWN, LEFT, & RIGHT arrow keys to highlight

the appropriate alpha characters.

4. Press the ENTER key to select a character and advance to the

next field of the Grid or Seq Note.

5. Use the CLR key to backspace if necessary.