14 control panel, Using the device – FRITSCH PULVERISETTE 14 User Manual

Page 40

Advertising
background image

6.14 Control panel

When the mill is switched on, the values of the last milling are displayed.

n

Timer: Range "P", "1"-"99" min, where "P" means continuous opera-

tion.

n

Speed: Range "6"-"20" (x1000 rpm), adjustable in steps of 1000, i.e.

a speed between 6000 and 20000 rpm can be selected.

n

Load lights up when the motor is overloaded by too much source

material.

n

Temperature: Off when operation is fault-free.
– Flashes at elevated temperatures. The current milling process

can still be carried out, but the sample feed rate should be

decreased. Afterwards, restarting is only possible after cooling

down.

– Continuously lit up at excessive temperatures; the motor is

switched off. Restarting is only possible after cooling down.

– Remains lit when the mill is switched on and when the tempera-

ture sensor is not in proper working order or is still too hot.

Using the device

- 40 -

Advertising