Page 11

Typical 6 - Load
Point Assembly
Installation

FIG. 14: SIX LOAD CELLS POSITIONED IN A

RECTANGULAR CONFIGURATION

NOTE:

In case there is some doubt concerning load point
assembly installation, contact your local Hardy
Dealer, or Hardy Application Engineering Depart-
ment or Customer Support Department for assistance.

You can orient the load point assemblies to meet your
system installation requirements. All load point

assemblies can be rotated 360

o

in 90

o

increments. The

examples above are recommendations only.

Level Requirements

For scales that must meet NIST Class 3 (OIML Class
3) specifications:

1.

The base plate support surfaces must be
within 0.2 degrees (0.4mm/100mm)

2.

The top plate support surfaces in the load
carrier must be within 0.5 degrees (0.9mm/
100mm)

For scales with accuracy requirements => 0.1%

1.

The base plate support surfaces must be
within 0.4 degrees (0.08mm/100mm)

2.

Top plate support surfaces in the load carrier
must be within 1 degree (1.8mm/100mm)

Stiffness

Load variations and external forces can cause support
surface level variations.