Hardy Floor Scales User Manual

Page 31

Advertising
background image

Hardy Floor Scales

22

Step 3.

Use a small slotted head screw driver and
disconnect the Load Sensor cable. It is a
good idea to mark the wires if the wire
markers have been removed. Color code
wires are as follows:

We recommend the use of C2 cable from the
weighing instrument to the junction box. Note the
color codes for C2 load points (left to right facing the
rear panel). Match the load sensor’s color coding to
ease trouble shooting.

Load Sensor #

Connector

Load Sensor #1

TB1

Load Sensor #2

TB2

Load Sensor #3

TB3

Load Sensor #4

TB4

To Instrument

TB5

Table 3: Summing Card Load Sensor Connectors

Load cell connector

Rear panel 9 pin

C2 cable TB9 7 pin

to Junction Box

Load cell color codes

3 pin connector

•

Shield Ground Wire

•

C2- Violet

•

C2+ Grey

•

EXC- Black

•

SEN- Brown

•

SIG- White

•

SIG+ Green

•

SEN + BLUE

•

EXC+ RED

• EXC- Black
• SEN- Brown
• EXC+ RED
• SEN+ BLUE
• Shield Ground Wire
• C2+ Grey
• C2- Violet
• SIG+ Green
• SIG- White

• EXC+ RED

• EXC- Black

• Shield Ground Wire

4 pin connector

• C2+ Grey

• C2- Violet

• SIG+ Green

• SIG- White