Zone 2 return zone 1 return, Figure 3 – Inovonics FA464DR User Manual

Page 5

Advertising
background image

© 1999 Inovonics Wireless Corporation 02039F.DOC LIT-FA464-INSTALL

5

hc:21-Nov-03

Connecting to a panel: When the FA464DR will be used with a hardwire security panel, the panel will typically
supply power and ground to the FA464DR (if the power supply provides the required current).

Typical connections between the FA464DR and a hardwire panel:

The installer wires the relay common terminal to the panel Zone Return, and wires either the Normally Open or
the Normally Closed terminal of the relay to the panel Zone input terminal.

13.6VDC

GROUND

PANEL ZONE 1

PANEL ZONE 2

PANEL

FA464DR

NOTE: GROUND

AND RETURNS
ARE NOT COMMON

ZONE 2 RETURN

ZONE 1 RETURN

In this example, Panel Zones 1 and 2

are configured to be N/C.