Current output report – Kistler-Morse KM Weigh II User Manual

Page 36

Advertising
background image

5-8

Chapter 5. Inputs and Outputs

16.

Press the F3 Key to access 20mA.

The display looks like this:

Either a ‘4’ or a ‘0’ will be in place of the
‘X.’ The unit of measure you set up in the
Units Menu shows in place of lbs.

17.

Use the keypad or the Up and Down

Arrow Keys to input a value for the weight
where you want the current transmitter to
output 20 mA. Press the Enter Key to
save the value in memory. The display
flashes a message acknowledging the
entry and returns to:

18.

Press the Menu Key to access the

second page of the menu. The display
shows:

19.

Press the F1 Key to access Net/Grs.

The display shows:

An asterisk indicates the current
selection.

20.

Press the F1 Key to select Net or

the F3 Key to select Gross. The display
flashes a message acknowledging your
selection and returns to:

21.

Press the F3 Key to select Fsafe.

The display shows:

An asterisk indicates the current
selection.

22.

Press the F1, F2, or F3 Key to

select the desired fail-safe condition. The
display flashes a message acknowledging
your selection and returns to:

23.

Press the Esc Key to return to the

Current Output Menu and repeat Steps 9
through 22 to set up additional outputs if
desired.

24.

Press the Esc Key to scroll up the

menu tree or press the Auto/Man Key to
return the display to vessel monitoring.

Current Output Report

The Weigh II allows you to view the slot and
channel number of the 4/0-20 mA current
outputs of any vessel in the system. Follow
this procedure.

1. If the Weigh II is in Auto Mode (Auto LED

illuminated), press the Auto/Man Key to
put the system in Manual Mode. The Auto
LED turns off.

2. Use the Up Arrow or Down Arrow Keys to

scroll to the desired channel.

3. Press the Menu Key to display the Main

Menu. The display shows:

4. Press the F2 Key to access the I/O Menu.

The display shows:

5. Press the F2 Key to access the Iout

Menu. The display shows:

6. Press the F3 Key to access the Rprt

Menu. The display flashes a message
stating:

The channel number you previously
scrolled to will be displayed after ID#.
The display then changes to:

Use the Arrow Keys to cycle between
the outputs.

X/20#Y HI VALUE

> Z lbs

F1 F2 F3

SET:

XmA 20mA

F1 F2 F3

SET:

Net/Grs FSafe

F1 F2 F3

OPERATION MODE

Net *Gross

F1 F2 F3

SET:

Net/Grs FSafe

F1 F2 F3

FAIL-SAFE MODE?

Lo* Hi NC

F1 F2 F3

WII MAIN MENU

Disp I/O Cal

F1 F2 F3

INPUT/OUTPUT MENU

Setpt Iout Serl

F1 F2 F3

CURRENT OUTPUT

Set Mode Rprt

F1 F2 F3

CURRENT OUTPUT

REPORT ON ID#:X

F1 F2 F3

1ST CURRENT OUTPUT

Slot XX Chan# YY

F1 F2 F3

SET:

Net/Grs FSafe

F1 F2 F3

Advertising