Kistler-Morse KM LD360s User Manual

Page 22

Advertising
background image

CAUTION: Only use
Sikaflex™ 1A polyure-
thane sealant or Dow
Corning™ RTV 739
or RTV 738. Other
sealants may contain
acetic acid, which is
harmful to sensors
and electronics.

4.

Route another 3-conductor cable through the fitting into
this junction box, and attach wires to the TB1 TB2 terminal:
black wire to B, white wire to W, and brown or red wire
to R.

5.

Repeat Steps 3 and 4 until all junction boxes on the
vessel are wired together.

6.

Route the cable from the last junction box through
conduit to the signal processor. Refer to the signal
processor manual for wiring the junction box to the signal
processor. One vessel takes up one channel in the signal
processor — the channel shows the average value from
all the Load Discs under the vessel.

Figure 3-9: Wiring Stainless Steel Junction Boxes Together and to Signal Processor