5.9.3

Test Results: Secondary Master Failure

The error scenario of a secondary master failure was simulated by stopping the TCSRV service on the

secondary master. The status agent was running during the tests.

The secondary master was stopped for 10 minutes, the test loop continued running. There was no

noticeable change in the performance of the primary master while it was running stand-alone, which means

that the tandem operation did not slow down the test workload.

After the secondary master was restarted it took about 45 minutes to update the primary master and come

back to the fault-tolerant mode.

The following performance values were measured on the primary master during the re-synchronization

phase. In the first test run the queue length of outbound faxes was below 700 and the TCOSS cache

worked well reducing disk reads to about 3 per second:

Object

Instance

Counter

Value

Physical Disk

D: (TCOSS)

Disk Writes/sec

99

Disk Write Bytes/sec

622,000

Disk Reads/sec

56

Disk Read Bytes/sec

883,000

%Disk Write Time

61

%Disk Read Time

2.3

TCOSS Disk

Read kB/sec

14

Reads/sec

3.4