Troubleshooting – Chicago Electric Power Tools 7" Angle grinder 67648 User Manual

Page 18

Advertising
background image

Page 18

For technical questions, please call 1-800-444-3353.

SKU 67648

troubleshooting

problem

possible causes

likely Solutions

Tool will not start.

Cord not connected.

1.

No power at outlet.

2.

Internal damage or wear. (Carbon

3.

brushes or switch, for example.)

Check that cord is plugged in.

1.

Check power at outlet. If outlet is

2.

unpowered, turn off tool and check circuit

breaker. If breaker is tripped, make sure

circuit is right capacity for tool and circuit

has no other loads.
Have technician service tool.

3.

Tool operates slowly.

Excess pressure applied to workpiece.

1.

Power being reduced by long or small

2.

diameter extension cord.

Decrease pressure, allow tool to do the

1.

work.
Eliminate use of extension cord. If an

2.

extension cord is needed, use one with

the proper diameter for its length and load.

See Extension Cords in GROUNDING

section.

Performance

decreases over time.

Carbon brushes worn or damaged.

Have qualified technician replace brushes.

Excessive noise or

rattling.

Internal damage or wear. (Carbon

brushes or bearings, for example.)

Have qualified technician service tool.

Overheating.

Forcing tool to work too fast.

1.

Blocked motor housing vents.

2.

Motor being strained by long or small

3.

diameter extension cord.

Allow tool to work at its own rate.

1.

Wear ANSI-approved safety goggles and

2.

NIOSH-approved dust mask/respirator

while blowing dust out of motor using

compressed air.
Eliminate use of extension cord. If an

3.

extension cord is needed, use one with

the proper diameter for its length and load.

See Extension Cords in GROUNDING

section.

Tool does not grind,

sand or wire brush

effectively.

Disc accessory may be loose on

1.

Spindle.

Disc accessory may be damaged, worn

2.

or wrong type for the material.

Check tightness of Outer Flange Arbor Nut

1.

or threaded disc accessory on Spindle. Be

sure disc accessory is of correct dimension

and Outer Flange Arbor Nut is tight.
Check condition and type of disc

2.

accessory. Use only proper type of disc

accessory in good condition.

Follow all safety precautions whenever diagnosing or servicing the tool.

disconnect power supply before service.