1.5 Product Drawings:
Details of some standard SAH filter systems are shown on the

following AAF drawings:
SAH Module

AAF Drawing Number

SAH-XXX-MD

114D-3025681

SAH-XXX-MD-MD

114D-3025657

SAH-XXX-2P-MD-MD-6F

114D-3025608

SAH-XXX-2P-MD-MD-MD-6F

114D-3025632

SAH-XXX-HD

114D-3025756

SAH-XXX-HD-HD

114D-3025772

SAH-XXX-2P-HD-HD-6F

114D-3025798

SAH-XXX-2P-HD-HD-HD-6F

114D-3025814

SAH-201-2P-CG

114D-3027513

SAH-XXX-CG

114D-3025848

SAH-XXX-CG-CG

114D-3025830

SAH-XXX-2P-CG-CG-6F

114D-3025822

Copies of the appropriate drawings will have been supplied as part

of the AAF submittals in response to the purchase order. Obtain and

review the drawing(s) before proceeding with the installation of the

filter system. The SAH filter system drawings include the following

details for filter system sizes 102 (1' high x 2' wide) through 810

(8' high x 10' wide):

– Overall filter system dimensions
– Shipping weights
– Operating weights
– Sizes and quantities of the particulate and gas-phase filters required
– Details of the gas-phase chemical media supplied
– Details of the particulate filters supplied
– System design airflow
– Pressure losses across the filter system at nominal airflow

design velocities

– Product details

1.6 Assembly - General Comments
As indicated previously, the individual components that will comprise

the filter system will ship separately and will be required to be installed

on site. The AAF Side Access Housing (SAH) is a self-contained

product and, consequently, a minimum amount of assembly is

required. Refer to section 3.0, Installation Instructions, of this manual

for further detailed instructions. Consult with an experienced installer

to obtain an accurate estimate of the time, personnel and equipment

resources, and tools that will be required to complete the assembly

and installation of the filter system. Site assembly will be limited to

Many combinations and permutations of housings and filter banks

can be supplied depending on the application and the requirements.

Typical Side Access Housing (SAH) model numbers are shown in

Table 1 where -XXX- represents the size of the Side Access Housing.

Housing sizes are designated as shown in the examples in Table 2.
This list by no means exhausts the possibilities and the system

provided may be different from those shown here. Consult the

AAF drawing that was supplied on the purchase order in question.

Table 1: Typical SAH Model Numbers

With gas-phase chemical filters but

With gas-phase chemical filters

With gas-phase chemical filters,

without particulate filters

and particulate filters

particulate filters, and fans.

SAH-XXX-MD

SAH-XXX-2P-MD-2P-6F

SAH-XXX-2P-MD-F-2P-6F

SAH-XXX-MD-MD

SAH-XXX-2P-MD-MD-2P-6F

SAH-XXX-2P-MD-F-MD-2P-6F

SAH-XXX-MD-MD-MD

SAH-XXX-2P-MD-MD-MD-2P-6F

SAH-XXX-2P-MD-MD-F-MD-2P-6F

SAH-XXX-HD

SAH-XXX-2P-HD-2P-6F

SAH-XXX-2P-HD-F-2P-6F

SAH-XXX-HD-HD

SAH-XXX-2P-HD-HD-2P-6F

SAH-XXX-2P-HD-F-HD-2P-6F

SAH-XXX-HD-HD-HD

SAH-XXX-2P-HD-HD-HD-2P-6F

SAH-XXX-2P-HD-HD-F-HD-2P-6F

SAH-XXX-CG

SAH-XXX-2P-CG-2P-6F

SAH-XXX-2P-CG-F-2P-6F

SAH-XXX-CG-CG

SAH-XXX-2P-CG-CG-2P-6F

SAH-XXX-2P-CG-F-CG-2P-6F

Table 2: Examples of Typical SAH Size Designations

Size designation

Nominal height (ft.)

Nominal Width (ft.)

SAH-404-

4

4

SAH-608-

6

8

SAH-810-

8

10