4 BG1600M Intermittent Pilot Ignition Control Installation Instructions

1

2

3

4

Power Supply. Provides disconnect means and overload protection as required.

Maximum cable length 48 inches (1,220 mm). (Resistive wire recommended.)

Alternate location for limit controller.

Controls in 24V circuit must not be in ground leg to transformer.

MV/PV
(COM)

PV

GN

D

B

URN

E

R

GND

24V

SENSE

SPARK

Thermostat

High

Temp

Limit

Pilot

Burner/Ignitor

Flame

Sensor

24VAC
Class 2
Transformer

IN

T

E

R

N

A

L

2

3

4

5

6

8

9

10

1

2

3

4

L1 (Hot)

L2 (Neu)

5

Combination

Gas Valve

TH

7

MV

5

Maximum cable length 48 inches (1,220 mm).

1

Chassis or Frame

Ground

6

Sensor rod must be 3/8” (9.53 mm) to 1/2” (12.7 mm) of the sensor tip should
be in the flame for proper sensing signal.

6

Figure 3: Wiring for 2 Rod Flame Sense without Vent Damper Jumper Plug

1

2

3

4

Power Supply. Provides disconnect means and overload protection as required.

Maximum cable length 48 inches (1,220 mm). (Resistive wire recommended.)

Alternate location for limit controller.

Controls in 24V circuit must not be in ground leg to transformer.

MV/PV
(COM)

PV

GN

D

B

URN

E

R

GND

24V

SENSE

SPARK

Thermostat

High

Temp

Limit

Pilot

Burner/Ignitor

Flame

Sensor

24VAC
Class 2
Transformer

IN

T

E

RNA

L

2

3

4

5

6

8

9

10

1

2

3

4

L1 (Hot)

L2 (Neu)

5

Combination

Gas Valve

TH

7

MV

5

Maximum cable length 48 inches (1,220 mm).

1

Chassis or Frame

Ground

6

Sensor rod must be 3/8” (9.53 mm) to 1/2” (12.7 mm) of the sensor tip should
be in the flame for proper sensing signal.

Use jumper
plug supplied
with control.

6

Figure 4: Wiring for 2 Rod Flame Sense with Vent Damper Jumper Plug