Step 6

Plug the AC power supply cable into the AC power source. Repeat Step 1 through Step 6 for the second power supply
(if present).

Connect DC-Input Power

Note

The color coding of the DC-input power supply leads depends on the color coding of the DC power source at your
site. Typically, green or green/yellow is used for ground. Make certain the lead color coding you choose for the
DC-input power supply matches lead color coding used at the DC power source.

Warning

When you install the unit, the ground connection must always be made first and disconnected last. Statement 42

Caution

The DC return connection to this system is to remain isolated from the system frame and chassis (DC-I).

Figure 17

Attaching the DC Power Cables

Step 1

At the rear of the router, check that the power switch is in the off (O) position.

Step 2

Ensure that the –V and +V leads are disconnected from the power source.

Step 3

Using a wire stripper, strip approximately 0.55 inch (14 mm) from the –V, +V, and ground leads (2).

Step 4

Insert the stripped end of the ground lead (1) all the way into the ground lead receptacle on the DC-input power supply,
and tighten the receptacle screw using a 3/16-inch flat-blade screwdriver.

Step 5

Insert the stripped end of the +V lead all the way into the +V lead receptacle and tighten the receptacle screw using the
same 3/16-inch flat-blade screwdriver. Repeat this step for the –V lead.

1

Ground lead service loop

3

Cable tie

2

DC power leads

4

Power switch