Replacing the thermocouple, Cleaning the pilot assembly, Cleaning the combustion chamber and flame arrestor – Kenmore POWER MISER 153.330652 User Manual

Page 22

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Replacing the Thermocouple

1.

Remove the Burner Door Assembly as directed
previously.

2.

Remove the retainer clip from the back of the two piece

wire connector and remove the two piece wire connector
from the assembly (Figure 27).

3.

Pull the thermocouple from the pilot assembly

(Figure 31).

IMPORTANT: Be careful not to bend or alter the position of the

pilot assembly components.

4.

Push the new thermocouple through the holes in the
pilot bracket. Insert the thermocouple tube into the holes
provided in the pilot assembly until it clicks into place.
Leave a small straight section entering and leaving the

two piece wire connector section for easier removal/
service.

5.

Position the new thermocouple through the opening of

the two piece wire connector (Figure 27). NOTE: The pilot
tube should be located at the top followed by the igniter

wire then the thermocouple.

6.

See “Replacing the Burner Door Assembly” section.

THERMOCOUPLE

PILOT

TUBE

TWO PIECE

WIRE CONNECTOR

RETAINER CLIP

FIGURE 27.

Cleaning the Pilot Assembly

1. Follow the procedure outlined In “Removing the

Burner Door Assembly”.

2. Use a soft bristle brush to remove any debris that

may have collected on the pilot. Note: Clean any
debris found In the primary air supply hole on the
pilot. See Figure 28.

3. Follow the steps In “Replacing the Burner Door

Assembly” section to reassemble.

External Inspection & Cleaning of the
Flame Arrestor

Although not likely to occur, if debris collects on the flame

arrestor, use a vacuum, compressed air, or a soft bristle brush

to remove it. NOTE: If unable to inspect or clean the flame

arrestor from underneath, follow the “Cleaning the Combustion

Chamber and Flame Arrestor” section instructions.

FIGURE 29

Cleaning the Combustion Chamber and

Flame Arrestor

1.

Follow procedure outlined in “Removing the Burner Door

Assembly” section.

2.

Use a vacuum cleaner/shop vac to remove all loose

debris in the combustion chamber (Figure 30). Use

compressed air to clear any dust or debris that may have

accumulated in the flame arrestor.

3.

Reassemble following the procedure under the “Replacing

the Burner Door Assembly” section.

FIGURE 28.