GROUNDING INSTRUCTIONS

It is important that all instructions for electrical connection and grounding be followed to eliminate any hazard or chance of

electrical short circuit Grounding reduces the risk of electric shock by providing an escape wire for the electric current

All electrical work must be in accordance with the National Electrical Code and all
local codes and ordinances.

WARNING

- Improper use of the grounding plug can result in a risk of electric

shock.

Electrical Requirements

The electrical requirements are a 120 volt 60 Hz, AC only, 15 amp or more fused

electrical supply. It is recommended that a separate circuit serving only the oven be
provided.

The oven is equipped with a 3-prong grounding plug, It must be plugged into a wail
receptacle that is properly installed and grounded Should you only have a 2-prong
outlet, have a qualified electrician install a correct wall receptacle.

A 3-prong adapter may be purchased and used temporarily if local codes allow.

Follow package directions.

A short power-supply cord is provided to reduce risk of becoming entangled in or
tripping over a longer cord.

Extension Cord

If it is necessary to use an extension cord, use only a 3-wire extension cord that has
a 3-blade grounding plug and a 3-slot receptacle that will accept the plug on the
microwave oven. The marked rating of the extension cord should be AC 115-120 volt,
15 amp. or more.

Be careful not to drape the cord over the countertop or table where it can be pulled
on by children or tripped over accidentally,.

Note:

1. If you have any questions about the grounding or electrical instructions, consult

a qualified electrician or serviceman.

2. Neither Sharp nor the dealer can accept any liability for damage to the oven or

personal injury resulting from failure to observe the correct electrical connection
procedures.

Radio or TV Interference

Should there be any interference caused by the microwave oven to your radio or TV,
check that the microwave oven is on a different electrical circuit, relocate the radio
or TV as faraway from the oven as feasible or check position and signal of receiving
antenna

3'Prong Plug

3-Prong Receptacle

Grounded

Receptacle Bo*

Permanent and Correct Installation

Grounding

Grounded

Receptacle Box