Power supplies – Cisco 5000 Series User Manual

Page 60

Advertising
background image

S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m

2-28

Cisco Nexus 5000 Series Hardware Installation Guide

OL-15902-01

Chapter 2 Cisco Nexus 5000 Series Overview

Cisco Nexus 5010 Switch

Power Supplies

The Cisco Nexus 5010 switch uses a front-end power supply. The chassis has slots for two power
supplies. Two power supplies can be used for redundancy, but the Cisco Nexus 5010 switch is fully
functional with one power supply.

Figure 2-34

shows the power supply, which has two LEDs: one for

power status and one for failure condition.

Figure 2-34

Power Supply for the Cisco Nexus 5010 Switch

Table 2-8

table describes the status of the two power supply LEDs.

A

Group 1, ports 1 through 8: 10-Gigabit
Ethernet and 1-Gigabit Ethernet capable
unencrypted ports

D

Group 2, ports 1 through 8: Fibre Channel
ports

B

Group 1, ports 1 through 16: Unencrypted
Ethernet ports

C

Group 1, ports 17 through 20: Encrypted
Ethernet ports

1

2

189955

1

Amber fail LED indicates a failure condition. 2

Green power LED indicates the power status.

Table 2-8

Power Supply LED Descriptions

Power Supply Condition

Power LED Status

Fail LED Status

No AC power to all power supplies.

Off

Off

Power supply failure, including overvoltage, overcurrent,
overtemperature, and fan failure.

Off

On