Service

A A

— DETAIL D —

Fluid Needle

Packings (47)

A. A

A

A

A

A

A

A

A

A

A

A

A A 30

SERVICE NOTES:

Gasket (33) must be replaced if fluid connector (67 or 1-see page 14) is removed or replaced.
Fluid leakage into air chambers may result if new gasket is not Instailed.

Lubricate threads

Apply anaerobic pipe sealant to threads

Apply high strength sealant to threads

Thread nut to bottom thread of needle

U-cup lips face inward

Torque to 23-27 ft-lb (31 -37 N*m)

Torque to 20-24 ft-lb (27-32 N«m)

Torque to 15-19 ft-lb (20-26 N»m)

Torque to 4-6 in-lb (5-8 N«m)