Operation

Select a Spray Tip

Use the Spray Tip Selection charts on page 18, as a
guide tor selecting an appropriate spray tip tor your
application. The fluid output and pattern width
depend on the size otthe spray tip, the fluid viscosity,
and the fluid pressure.

NOTE:

When spraying very low viscosity fluids, use

the optional fluid needle 220-413 (see page 15). The

standard needle may not provide positive shut otf tor
such fluids.

Install a Spray Tip

WARNING

To reduce the risk ot a fluid injection injury. Always
tollow the

Pressure Relief Procedure

on page 3

before removing or installing a spray tip.

Install a spray tip in the gun. The air cap and spray tip
position determines the direction ot the spray pattern.

Rotate the air cap (the spray tip rotates with it) as
needed for the desired spray pattern direction. See
Fig. 2.

Adjust the Spray Pattern & Apply the Fluid

WARNING

To reduce the risk ot serious injury, including fluid

injection, and splashing in the eyes or on the skin:

1. Never point the spray gun at anyone or any part

of the body or put your hand or fingers over the
spray tip when adjusting the spray pattern or
spraying fluid.

2. Always engage the trigger safety latch when you

stop spraying. See Fig. 3.

3.

Never exceed the maximum air and fluid work­

ing pressure of the lowest rated component in
your system. See

System Pressure

in the

EQUIPMENT MISUSE HAZARD

Section on

page 5.

Vertical Spray Pattern Horizontal Spray Pattern

Safety Latch Disengaged

or in

O FF S A FE

Position

Pattern

Adjustment

Knob

Safety Latch Engaged
or in

O N S A FE

Position

Fig. 3

1. Set the fluid pressure at 300 psi (21 bar).

2. Trigger the gun to check the atomization; do not

be concerned about the pattern shape yet.

No Air

Fig. 4

Too Little Air

Right Amount

of Air

8

307-947

Advertising