Ventilate the spray booth warning, Required accessories, Ventilate the spray booth – Graco HIGH EFFICIENCY LOW PRESSURE AA2000 User Manual

Page 6: Installation

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation

KEY
A

Gun Air Inlet

G

Pump Ground Wire

B

Gun Fluid Inlet

H

Air Line Filter

c

Bleed-Type Master

J

Fluid Drain Vaive

Air Vaive

K

Gun Air Hose

D

Main Air Supply Line

L

Gun Fluid Hose

E

Pump Air Regulator

M

Fluid Regulator Kit

F

Gun Air Regulator,

N

Fluid Filter

p/n 110-776, lOpsI

(0.7 bar)Maximum
Outlet Pressure

P

Air Pressure

Relief Vaive

Fig.1

The typical installation shown in Fig.1 is only a guide
for selecting and installing air-assisted airless spray

systems. It is not an actual system design. Contact
your Graco representative for assistance in designing
a system to meet your needs.

The Graco fluid pump Model 217-523 is designed for

use in air-assisted airless systems. It has a maximum
working pressure of 950 psi (66 bar). See instruction

manual 307-595 for information on this pump.

Ventilate the Spray Booth

----------------------- WARNING----------------------------

Required Accessories

To prevent hazardous concentrations of toxic and/

or flammable vapors, spray only in a properly ven­

tilated spray booth.

Never operate the spray gun unless ventilation

fans are operating.

Check and follow all of the National, State and

Local codes regarding air exhaust velocity

requirements.

■WARNING

Two accessories, the bleed-type master air valve

(C), and the fluid drain valve (J) are required for

your system to reduce the risk of serious injury
from moving parts, splashing, or fluid injection

when shutting off the pump.

The bleed-type master air valve

(located down­

stream of the pump air regulator) relieves air
trapped between the valve and the pump, after
the pump is shut off. Trapped air can cause the

pump to cycle unexpectedly and result in serious
injury if you are adjusting or repairing the pump.

The fluid drain valve(s)

helps relieve fluid pressure

in the displacement pump, hose and gun when
shutting off the pump. Triggering the gun to relieve

pressure may not be sufficient, especially if there

is a clog in the hose, gun, or tip.

6

307-947

Advertising