Consult with the service shop or authorized personnel

The following will change wiring conditions inside the camera head. We recommend
you to use the service shop or authorized service personnel.

(B) Changing from left side to right side

Changing from left side

to right side

Procedures

Description on

procedures

From left side @

To right side®

Turn to right with 180°

1. Remove 2 securing

screws on the back panel.

2. Pull out flexible PC board

from back panel, and

rotate entire back panel
by 180° in clockwise
direction (take care not to
break wiring leads).

3. Restore flexible PC board

on back panel again and

firmly tighten 2 screws.

Cautions:

• Take care not to apply tension and torque exceeding 180° to the wiring material,

because this may change wiring conditions inside the unit. Also take care not to

twist the flexible PC board. If twisted, it may cause break down of wiring leads or

damage circuits inside the camera head

• (A) and (B) will be made in combination as required.