Comtrol ES7506 User Manual

Page 10

Advertising
background image

10 - Connect the Power and Ground

RocketLinx ES7506 User Guide: 2000529 Rev. F

Hardware Installation

b.

Tighten the wire-clamp screws to prevent the wires from coming loose.

• PWR1 and PWR2 support power redundancy and reverse polarity protection.

• Accepts a positive or negative power source but PWR1 and PWR2 must apply to the same mode.

• If both power inputs are connected, the ES7506 is powered from the highest connected voltage.

• The ES7506 can emit an alarm if PWR1 or PWR2 are no longer receiving power. See

Warning

discussion on

Page 81

to configure an alarm.

2.

Connect a ground wire between the chassis and
earth ground using 12-24AWG wire to ensure
that the ES7506 is not damaged by noise or
electrical shock.

a.

Loosen the earth ground screw on the right
side of the ES7506.

b.

Insert the ground wire.

c.

Tighten the ground screw after the earth
ground wire is connected.

AC Power Input

Power Supply

24-55VDC/2.5A

(UL Listed)

V-

V+

AC Power Input

Power Supply

24-55VDC/2.5A

(UL Listed)

V-

V+

24-55VDC

DC Power Output

12-24AWG

DC Power Output

24-55VDC

12-24AWG

PWR 1

PWR 2

Alm

Wiring Positive Power Supplies

Advertising