Comtrol ES7506 User Manual

Page 137

Advertising
background image

RocketLinx ES7506 User Guide: 2000529 Rev. F

Warnings (CLI) - 137

Configuration Using the Command Line Interface (CLI)

Event Selection

Event Selection

Switch(config)# warning-event
coldstart Switch cold start event
warmstart Switch warm start event
linkdown Switch link down event
linkup Switch link up event

authentication Authentication failure event

fault-relay Switch fault relay event

poe-powering Switch PoE powering or unpowered event
power Switch power failure event

super-ring Switch super ring topology change event
time-sync Switch time synchronize event

Example:

Cold Start event

Switch(config)# warning-event coldstart
Set cold start event enable ok.

Example:

Link Up event

Switch(config)# warning-event linkup
[IFNAME] Interface list, ex: fastethernet1 or gi1
Switch(config)# warning-event linkup fastethernet1
Set fa5 link up event enable ok.

Display

Switch# show warning-event
Warning Event:
Cold Start: Enabled
Warm Start: Disabled
Authentication Failure: Disabled
Link Down: fa4-5
Link Up: fa4-5
Power Failure:
Super Ring Topology Change: Disabled
Fault Relay: Disabled
Time synchronize Failure: Disabled
PoE Powering: fa1-4

Syslog Configuration

Local Mode

Switch(config)# log syslog local

Server Mode

Switch(config)# log syslog remote
192.168.250.33

Both

Switch(config)# log syslog local
Switch(config)# log syslog remote 192.168.250.33

Disable

Switch(config)# no log syslog local

Advertising