Comtrol ES7506 User Manual
Page 137

RocketLinx ES7506 User Guide: 2000529 Rev. F
Warnings (CLI) - 137
Configuration Using the Command Line Interface (CLI)
Event Selection
Event Selection
Switch(config)# warning-event
coldstart Switch cold start event
warmstart Switch warm start event
linkdown Switch link down event
linkup Switch link up event
authentication Authentication failure event
fault-relay Switch fault relay event
poe-powering Switch PoE powering or unpowered event
power Switch power failure event
super-ring Switch super ring topology change event
time-sync Switch time synchronize event
Example:
Cold Start event
Switch(config)# warning-event coldstart
Set cold start event enable ok.
Example:
Link Up event
Switch(config)# warning-event linkup
[IFNAME] Interface list, ex: fastethernet1 or gi1
Switch(config)# warning-event linkup fastethernet1
Set fa5 link up event enable ok.
Display
Switch# show warning-event
Warning Event:
Cold Start: Enabled
Warm Start: Disabled
Authentication Failure: Disabled
Link Down: fa4-5
Link Up: fa4-5
Power Failure:
Super Ring Topology Change: Disabled
Fault Relay: Disabled
Time synchronize Failure: Disabled
PoE Powering: fa1-4
Syslog Configuration
Local Mode
Switch(config)# log syslog local
Server Mode
Switch(config)# log syslog remote
192.168.250.33
Both
Switch(config)# log syslog local
Switch(config)# log syslog remote 192.168.250.33
Disable
Switch(config)# no log syslog local