Hardware installation, Connect the power and ground – Comtrol ES7506 User Manual
Page 9

RocketLinx ES7506 User Guide: 2000529 Rev. F
Hardware Installation - 9
Hardware Installation
You can use the following subsections to install the RocketLinx ES7506:
•
•
Connect the Alarm Relay Output
•
•
•
Connect the Power and Ground
You can use the following procedure to connect power and the ground to the ES7506.
1.
Connect the DC power inputs.
a.
Insert positive and negative wires (12-24AWG) into the PWR+ and PWR- contacts.
Note: Power should be disconnected from the power supply before connecting it to the switch.
Otherwise, your screw driver blade can inadvertently short your terminal connections to the
grounded enclosure.
Electrical Specifications
Values
Power Input Voltage
PWR1/PWR2
IEEE 802.3af Standard, Manual
48 (48-57VDC)
IEEE 802.3af Ultra
55 (55-57VDC)
Forced 15.4W
48 (48-57VDC)
Forced 30W
55 (55-57VDC)
PoE Output Voltage
IEEE 802.3af Standard, Manual
44-57V
IEEE 802.3af Ultra
50-57V
Forced
44-57V
Maximum PoE
Power/Port
IEEE 802.3af Standard, Manual
15.4W
IEEE 802.3af Ultra, Forced
30W
Total Power Budget
Maximum
Up to 100 W
Power Consumption
Maximum
8W without PD load