Establishing a telnet connection – Comtrol UP 16-Port User Manual

Page 43

Advertising
background image

DeviceMaster UP 16-Port Hardware User Guide: 2000596

Rev. B

RedBoot Procedures - 43

RedBoot Procedures

Establishing a Telnet Connection

Use the following procedure to telnet to the DeviceMaster UP.

1.

Open a telnet session, enter the DeviceMaster UP IP address.

If using Windows, you can use PortVision DX, see

Accessing RedBoot

Commands in Telnet/SSH Sessions (PortVision DX)

on Page 37.

2.

Press the Enter key if you did not program a password or type the password
and press Enter.

Note: The DeviceMaster UP does not come pre-programmed with a password.

3.

Type reset, and close the session.

4.

Open a new telnet session, enter the DeviceMaster UP IP address, and the
password.

5.

Type dis to disable the Bootloader.

6.

Verify that the system responds with a Loading disabled message.

♥♦

Password:

Comtrol DeviceMaster RTS Model ID: 5002111

SocketServer 9.35
Built: Fri May 09 09:48:40 CST 2014
IP Addr: 192.168.11.23, Mask: 255.255.0.0, Gateway: 192.168.0.254
MAC Addr: 00:c0:4e:07:ff:fc

dm> reset

*********************************************
**
** Comtrol DeviceMaster Bootloader Version 3.36
** RedBoot(tm) environment - built 07:24:15, Jan 8 2014
** Platform: Comtrol DeviceMaster (ARM 7TDMI)
** Portions Copyright (C) 2000. Red Hat, Inc.
** Portions Copyright (C) 2001-2013 Comtrol Corp.
*********************************************

RAM: 0x00000000-0x007c0000 (0x00000000 - 0x07b00000 available)
FLASH: 0x05000000 - 0x053fffff, 64 x 0x10000 blocks
RedBoot> dis
Loading disabled
RedBoot> _