SERIES VF-100 SCREW FEEDER

9

Agitator Eccentric (Flexible wall agitation option only): The agitator eccentric is mounted

to the motor shaft behind the drive coupling. It is subject to wear and should be checked

as part of a preventive maintenance routine. To check the eccentric, remove main

power from the feeder controller. Remove the drive guard. If more than 1/8” free play

side to side is observed between the eccentric and the follower “Fingers”, replace the

eccentric

Hopper Membrane (Flexible wall agitation option only): Inspect the membrane from time

to time for splitting or brittleness. Replace as required.















GEARMOTOR

AGITATOR DRIVE ASSEMBLY, FIG-3

ECCENTRIC, P/N 410033

DRIVE RODS, P/N 410126

AGITATOR BEARINGS, P/N 410028

DRIVE SHAFT

CRANK ARM, P/N 410037