Series vf-100 screw feeder – Eagle Microsystems VF100 User Manual

Page 8

Advertising
background image

SERIES VF-100 SCREW FEEDER

7

the SCR, start the motor and check the rotation again. Once the rotation has been

proven to be correct and the screw is fully secured to the drive shaft, you are ready to

fill the hopper with material.

B. DETERMINE ACTUAL FEED RATES:

Actual feed rates vary in accordance with material density, material flow

characteristics and ambient environmental influences. For accurate results it is

important that you determine the actual feed rates you can expect at different settings

of the speed potentiometer and, in the case of a feeder equipped with the remote

analog speed control option, different control input levels. This is best accomplished

with an accurate portable scale and a timing device. Recording the weight of material

fed over a reasonable period of time at various settings will allow you to develop a

very accurate feed rate table for your particular conditions.


C. OPERATION:

The basic VF-100 controller consists of the following controls:

1 POWER ON/OFF SWITCH: Switches main power to

the controller, feeder drive motor and any optional

device powered from the controller.

2 FEEDER MANUAL/OFF/REMOTE SWITCH: The "MANUAL"

setting allows local operation of the feeder drive motor

via the controller mounted speed dial. The "OFF" setting

disconnects power to the feeder drive motor. The “REMOTE"

setting allows the feeder to start/stop from a remote RELAY contact supplied by

the customer.

3 FEEDER SPEED DIAL: Controls feeder speed as a percentage of full rated speed.

POWER

ON

OFF

60

40

FEEDER

AUTO

MANUAL

OFF

0

20

30

10

100

70

90

80

50

FEEDER SPEED

Advertising