6.3

Temperature-controlled hard blast chilling and storage

The temperature-controlled hard blast chilling and storage cycle is divided into the following three phases:

-

blast chilling hard phase

-

blast chilling

-

storage.

On conclusion of a phase, the device passes automatically to the next.

Operate as indicated to start the cycle:

1.

Make sure the device is in the "on" status.

2.

Make sure that the keyboard is not locked and that no procedure is in progress.

3.

Press and release the key (1), press and release the key (2) and then press and release the key (3) and finally

press and release the key (4): the device will display the blast chilling end temperature and the work set-point

during blast chilling.

4.1

Press and release the MENU key and then press and release the key (4) or the key (5) to select the blast

chilling end temperature and the work set-point during blast chilling.

4.2

Press and release the key + (6) or the key – (7) to modify these values and then the ESCAPE key to memorise

them; these values can also be memorised through parameters r3 and r7.