13 pre-cooling start-up – EVCO EVCSR818P9EF User Manual
Page 45

EVCO S.p.A.
Vcolor 818
| Installer manual ver. 1.1 | Code 144VC818E114
page 45 of 94
Operate as follows to exit the procedure:
8.
Press and release the ESCAPE key or do not operate for 60 s.
The fan is switched on at the selected speed after 5 s from release of the key (1) or the key (2).
6.13
Pre-cooling start-up
Every operating cycle can be preceded by pre-cooling.
Operate as indicated to start pre-cooling:
1.
Make sure the device is in the "on" status.
2.
Make sure that the keyboard is not locked and that no procedure is in progress.
3.
Press and release the key (1) and then press and release the START/STOP key (2).
Operate as indicated to cut-off pre-cooling:
4.
Press and hold the START/STOP key 3 s.
Parameter r120 establishes the work set-point during pre-cooling.
When the cabinet temperature reaches that established with parameter r12, pre-cooling continues and the buzzer is
activated for 2 s.