EVCO EVF818P9 User Manual
Page 7

EVCO S.p.A.
EVF818 | Installer manual ver. 1.0 | Code 144F818E104
page 7 of 76
1.2
Summary table of the main features and the models
available
The following table illustrates the main features of the device and the models available.
“ / “ indicates the feature can be set via a configuration parameter.
User interface (without cover)
EVF818
340.0 x 84.0 mm (13.385 x 8.400 cm; L x H)
•
custom 3 + 4 + 1 digit display (with function icon)
•
number of keys (capacitive touch-key type)
10
Control module (without cover)
EVF818
166.0 x 116.0 mm (6.535 x 11.598 cm; L x H)
•
Connections
EVF818
faston + fixed screw terminal board + removable screw
terminal board
•
Power supply
EVF818
115... 230 VAC
•
Analogue inputs
EVF818
cabinet probe
PTC/NTC
needle probe 1
PTC/NTC
needle probe 2
PTC/NTC
needle probe 3
PTC/NTC
evaporator probe
PTC/NTC
condenser probe
PTC/NTC
Digital inputs (for NO/NC contact)
EVF818
door micro switch
•
high pressure
•
low pressure
•