EVCO EVF818P9 User Manual

Page 8

Advertising
background image

EVCO S.p.A.

EVF818 | Installer manual ver. 1.0 | Code 144F818E104

page 8 of 76

compressor circuit breaker protection

•

Analogue outputs (PWM)

EVF818

evaporator fan

(1)

Digital outputs (electromechanical relays; A res. @

250 VAC)

EVF818

compressor

30 A

defrosting

8 A

evaporator fan

(1)

condenser fan

8 A

door heating elements

8 A

needle probe heating

16 A

cabinet light/UV light

8 A

pump down valve/alarm

8 A

Communication port

EVF818

TTL type serial port

•

RS-48 serial port with MODBUS communication protocol

•

Other features

EVF818

IP65 protection rating of the user interface

IP65

clock

•

signal buzzer and alarm

•

management of three types of backlight

•

management of blast chilling and storage/deep freezing

and storage cycles

•

management of temperature/time controlled operation

cycles

•

hard/soft operating cycles management

•