7 Empty the container used to collect the

liquid dispensed by the machine and
place it under the steam wand.

8 Turn the knob clockwise and set it to the

” position. The machine starts the

rinse cycle.

10 Rinse the water tank thoroughly and

refi ll it with fresh drinking water.

11 Empty the container used to collect the

liquid dispensed by the machine.

9 When the water in the tank is fi nished,

the icon on the side is displayed to
indicate that the knob must be brought
back to the “ ” position.

12 Place a large container under the

dispensing spout.

Steady on

13 Before starting the procedure, check

that the following icons are displayed.

Steady on

Warning! Remove the "In-
tenza" fi lter before adding the

descaling solution.

• Pour the entire content of the GAGGIA

concentrated descaling solution into
the water tank, and then fi ll the tank
with fresh drinking water up to the
MAX level. Place the tank back into the
machine.

Steady on

1 Place a container under the steam

wand.

Use a container of at least
1 litre capacity. If you do

not have a container of this capac-
ity, once it is fi lled close the knob,
empty the container and then place
it again under the wand and repeat
the procedure.

2 Only after adding the descaling solution

in the tank, turn the knob clockwise to
the “

” position and dispense 2-3

cups of water (approx. 150 ml).

3 Stop dispensing by turning the knob

back to its position “ ” .

4 Let the descaling solution take eff ect

for 10 minutes.

5 Repeat steps 2 and 3 at intervals of 3

minutes, until there is no descaling
solution left in the water tank.

6 When the icon is displayed, rinse the

water tank thoroughly and refi ll it with
fresh drinking water.