5 performance monitoring for ethernet cards, 1 e-series ethernet statistics window – Cisco ONS 15454 SDH User Manual

Page 14

Advertising
background image

15-14

Cisco ONS 15454 SDH Reference Manual, R4.6

April 2008

Chapter 15 Performance Monitoring

15.5 Performance Monitoring for Ethernet Cards

15.5 Performance Monitoring for Ethernet Cards

The following sections define performance monitoring parameters and definitions for the E-Series,
G-Series, and ML-Series Ethernet cards.

15.5.1 E-Series Ethernet Card Performance Monitoring Parameters

CTC provides Ethernet performance information, including line-level parameters, port bandwidth
consumption, and historical Ethernet statistics. The E-Series Ethernet performance information is
divided into the Statistics, Utilization, and History tabbed windows within the card view Performance
tab window. The following sections describe PM parameters provided for the E100T-G and E1000-2
Ethernet cards.

15.5.1.1 E-Series Ethernet Statistics Window

The Ethernet statistics window lists Ethernet parameters at the line level. The Statistics window provides
buttons to change the statistical values shown. The Baseline button resets the displayed statistics values
to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which
automatic refresh occurs.

Table 15-15

defines the E-Series Ethernet card Statistics parameters.

HP-ESR

High-Order Path Errored Second Ratio (HP-ESR) is the ratio of errored
seconds to total seconds in available time during a fixed measurement
interval.

HP-SESR

High-Order Path Severely Errored Second Ratio (HP-SESR) is the ratio
of SES to total seconds in available time during a fixed measurement
interval.

HP-BBER

High-Order Path Background Block Error Ratio (HP-BBER) is the ratio
of BBE to total blocks in available time during a fixed measurement
interval. The count of total blocks excludes all blocks during SESs.

Table 15-14 VC4 High-Order Path PM Parameters for the Near-End and Far-End

DS3i-N-12 Cards (continued)

Parameter

Definition

Table 15-15 E-Series Ethernet Statistics Parameters

Parameter

Meaning

Link Status

Link integrity indicator (up means present, and down means
not present).

Rx Packets

Number of packets received since the last counter reset.

Rx Bytes

Number of bytes received since the last counter reset.

Tx Packets

Number of packets transmitted since the last counter reset.

Tx Bytes

Number of bytes transmitted since the last counter reset.

Rx Total Errors

Total number of receive errors.