Chapter 15 Performance Monitoring

15.5.2 G-Series Ethernet Card Performance Monitoring Parameters

15.5.2.1 G-Series Ethernet Statistics Window

The Ethernet statistics window lists Ethernet parameters at the line level. The Statistics window provides
buttons to change the statistical values shown. The Baseline button resets the displayed statistics values
to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which
automatic refresh occurs. The G-Series Statistics window also has a Clear button. The Clear button sets
the values on the card to zero, but does not reset the G-Series card.

Table 15-18 on page 15-17

defines the G-Series Ethernet card Statistics parameters.

Table 15-18 G-Series Ethernet Statistics Parameters

Parameter

Meaning

Time Last Cleared

A time stamp indicating the last time statistics were reset.

Link Status

Indicates whether the Ethernet link is receiving a valid
Ethernet signal (carrier) from the attached Ethernet device;
up means present, and down means not present.

Rx Packets

Number of packets received since the last counter reset.

Rx Bytes

Number of bytes received since the last counter reset.

Tx Packets

Number of packets transmitted since the last counter reset.

Tx Bytes

Number of bytes transmitted since the last counter reset.

Rx Total Errors

Total number of receive errors.

Rx FCS

Number of packets with a Frame Check Sequence (FCS)
error. FCS errors indicate frame corruption during
transmission.

Rx Alignment

Number of packets with received incomplete frames.

Rx Runts

Measures undersized packets with bad cyclic redundancy
check (CRC) errors.

Rx Shorts

Measures undersized packets with good cyclic redundancy
check (CRC) errors.

Rx Jabbers

Total number of frames received that exceed the 1548-byte
maximum and contain CRC errors.

Rx Giants

Number of packets received that are greater than 1530 bytes
in length.

Rx Pause Frames

Number of received Ethernet IEEE 802.3z pause frames.

Tx Pause Frames

Number of transmitted IEEE 802.3z pause frames.

Rx Pkts Dropped Internal
Congestion

Number of received packets dropped due to overflow in
G-Series frame buffer.

Tx Pkts Dropped Internal
Congestion

Number of transmit queue drops due to drops in the G-Series
frame buffer.

HDLC Errors

High-level data link control (HDLC) errors received from
SDH/SONET (see note).

Rx Unicast Packets

Number of unicast packets received since the last counter
reset.

Tx Unicast Packets

Number of unicast packets transmitted.