18
TVE-DEC10 IP Video Decoder User Manual
Transparent channel
Use this menu to set up to transmit transparent data between the encoder and
decoder. The decoder uses the RS-232 or RS-485 serial port to send transparent
data over the network.
Up to 64 encoders can be used to address a decoder.
Note: If RS-232 is selected as the local serial port, you must set up the operation
mode as transparent under Configuration > Serial Port Parameters > RS-232.
To set up the transparent channel:
1. Click
Decoding Operation
>
Transparent Channel.
The Transparent
Channel window appears.
2. Enter values for the following parameters:
Local serial port
: Select the decoder’s serial interface from the drop-down
list: RS-232 or RS-485.
Remote serial port
: Select the remote encoding device’s serial interface from
the drop-down list: RS-232 or RS-485.
Remote host IP: Enter the IP address of the remote encoding device.
Remote host port: Enter the host port of the remote encoding device.
User ID/password: Enter the user name and password used to log into the
encoding device.
3. Click
Save
to save the settings.