UL Specifications

Part

Loop

Electrical

Gap

Number

Type

Configuration

Distance

*

1065W

Closed

N.O.

2"

1070

Open or Closed

SPDT

1

/

2

"

1075

Closed

N.O.

1

/

2

"

1075W

Closed

N.O.

1

1

/

4

"

*

Gap Specifications are nominal and may vary

±

20%. Gap Specifications are for switch to make.

Break distance is approximately 1.1 to 1.5 times make.

**

European Union Specifications: 48 V AC/DC max, 0.5 Amp

**

FORM A (1065W, 1075, 1075W)

FORM C (1070)

Voltage: 100 V AC/DC max

Voltage: 30 V AC/DC max

Current: 0.5 A max

Current: 0.25 A max

Power: 7.5 W max

Power: 3.0 W max

WARNING: Each electrical rating is an individual maximum and cannot be exceeded!

C-UL Specifications

All Contacts: 30 VDC, 50 mA max

Gap Specifications:*
See UL Gap Specification

1075 Series

3

/

8

" Diameter Press-Fit with Wire Leads

Installation Instructions

1. Drill appropriate diameter and depth holes for contact and magnet (

3

/

8

" x 1

1

/

3

" for contacts

and

3

/

8

" x 1

1

/

2

" for 1065W magnets,

3

/

8

" x 1

1

/

3

" for 1070, 1075, and 1075W magnets).

2. Connect contact leads to security system loop and test for continuity.

3. Lightly coat the contact and magnet with RTV mounting compound (Part Number 1905)

and insert into respective holes.

.36"

0.91cm

Magnet

Part No. 1924

(Included)

.44"

1.12cm

1.30"

3.30 cm

1.30"

3.30cm

.03"

0.08cm

PK-0985 Rev H 07/02

www.GE-InterlogixSecurity.com

2266 Second Street North
North St. Paul, MN 55109
Phone: 651-777-2690
USA & Canada: 800-777-5485
Technical Service: 800-777-2624

12345 SW Leveton Drive
Tualatin, OR 97062
Phone: 503-692-4052
USA & Canada: 800-547-2556
Technical Service: 800-648-7424
Faxback: 800-483-2495

GE Interlogix

Made in Taiwan

Advertising