Ulc specifications, Ul specifications – Interlogix 1078CT Series User Manual

Page 2

Advertising
background image

1078CT Series 3/4" Diameter Steel Door with Terminals
Magnetic Contacts

Installation Instructions

For 1078CT
1. Drill 3/4" diameter and 1 5/8" deep

holes for contacts and 3/4"
diameter and 1 1/2" deep holes for
magnets.
Hole saw arbors available from
Sentrol.

2. Strip wire from security system

loop, insert into terminal block and
tighten. Test for continuity.

3. Lightly coat the contact and

magnet with RTV mounting
compound (Sentrol part number
1905) and insert into respective
holes.

For R1078CT
1. Drill 3/4" diameter and 1 5/8" deep

hole for contact. The 1840 Magnet
is designed to be mounted in the
top channel of a metal entry/exit
door. The magnet can be rotated to
accommodate either wide or
narrow top channels.

2. Clean top channel of door.
3. Position magnet opposite switch in

top of door channel.

4. Lightly coat the contact and magnet

with RTV mounting compound
(Sentrol par number 1905) and
mount into respective locations.

13960 Rev C 11/01

**

FORM A (1078CT, 1078CTW, R1078CT)

Voltage: 100 VAC/DC Max
Current: 0.5 A Max
Power: 7.5 W Max

*

Gap Specifications are nominal and may vary

±

20% due to temperature. Gap Specifications

are for switch to make. Break distance is
approximately 1.1 to 1.5 times make.

0.94"

2.36 cm

1.63"

4.13 cm

1.56"

3.96 cm

Magnet

Part No. 1929

(included)

0.38"

0.95 cm

0.75"

1.91 cm

1078CT

R1078CT

ULC Specifications

All Contacts: 30 VDC, 50 ma max. Gap Specifications:*

See UL Gap Specifications

Part

Loop

Electrical

Gap Distance

Number

Type

Configuration

In Wood In Steel

1078CT

Closed

N.O.

7/8" 3/8"

1078CTW

Closed

N.O.

2" 3/4"

R1078CT

Closed

N.O.

N/A 5/8"

UL Specifications

**European Union Specifications: 48 VAC/DC Max., 0.5 Amp

0.94"

2.36 cm

1.63"

4.13 cm

0.89"

2.26 cm

1.63"

4.13 cm

1.81"

4.60 cm

0.63"

1.59 cm

0.50"

1.27 cm

Magnet

Part No. 1840