Setting the sensitivity, mode, and led jumpers, Pet immunity, Pet alley application – Interlogix AP950PI User Manual

Page 3: Red. see “setting the sensitivity, mode, and, Led jumpers

Advertising
background image

Setting the sensitivity, mode, and LED

jumpers

The unit provides three jumpers to set sensitivity, mode, and

the LED. See Figure 3 on page 2.

Figure 7: Sensitivity

Standard Sensitivity (factory default) - Reduces
sensitivity and range for use with the pet immune mirror.
Range = 35 feet (10.7m). Both pins must be covered to place
the unit in Standard Sensitivity.

Increased Sensitivity - Increases sensitivity and range for
use with the standard mirror. Range = 50 feet (15.2m). Either
pin can be uncovered to place the unit in Increased
Sensitivity.

Figure 8: Mode

BI= Bi-Curtain Mode (factory default). Increases
false alarm immunity in smaller areas. Requires the intruder
to pass through two curtains to trigger an alarm. Do not use
for single curtain applications or ranges under 5 feet (1.5m).
Both pins must be covered to place the unit in Bi-Curtain
Mode.

STD= Standard Curtain Mode. Use for wide-angle or
single-curtain applications. Requires the intruder to only
pass through one curtain to trigger an alarm. Either pin can
be uncovered to place the unit in Standard Curtain Mode.

Note: Operation of the AP950PI in the Standard Curtain Mode

is UL 639 Listed for a range of 35 feet (10.7m) with both

mirrors in Standard Sensitivity, and for a range of 50 feet

(15.2m) with the standard mirror in Increased Sensitivity. For

operation in Bi-Curtain Mode, the unit is UL 639 Listed for 30

feet (9.1m) range only. For ranges from 30 to 50 feet (9.1 to

15.2m) with sensitivity set to Increased and Bi-Curtain mode,

the unit is not UL 639 Listed but will provide detection within 6

steps or 14 feet (4.3m) across the plane of coverage. UL has

not tested the 6 steps or 14 foot (4.3m) detection.

Figure 9: LED

To enable the LED (factory default), both pins
must be covered by the jumper.

To disable the LED, either pin can be uncovered.

Note: The LED only lights if an alarm occurs and the jumper is

covering both pins.

Pet immunity

When mounted properly, the unit provides false alarm

immunity to dogs and similar animals. The size and body

temperature of the animal, which depends on the length of the

animal's coat, affects the immunity to false alarms. Dogs vary

in body temperature by breed. A very warm-blooded dog with

short hair will not be as immune to false alarms as a similar

dog with long hair. Therefore, the acceptable short hair dog is

limited to a lighter weight dog. See the examples listed in the

following table:

Long hair (2”
long) up to 80
lbs.

Medium hair
(1.5” long) up
to 50 lbs.

Short hair (1”
long) up to 30
lbs.

Not
recommended
use pet alley
application

Chow Chow

Collie

Welsh Corgi

Doberman

Husky

English Setter

Border Terrier

Great Dane

Standard Poodle

(uncut)

Border Collie

Cocker Spaniel

Greyhound

Retriever

Springer Spaniel

French Bulldog

Mastiff

Sheepdog

Shetland

Sheepdog

Pug

Pit Bull

Shepherd

Cats

Malamute

Note: To reduce false alarms, keep animals off the furniture

and avoid aiming the unit at stairs.

Pet immunity not verified by UL.

Pet alley application

To create a detection-free area close to the floor, mount the

unit 3.5 feet (1.1m) above the floor, upside down (detector

window towards the ceiling). Use the standard mirror and set

the J2 jumper for Increased Sensitivity (both pins cannot be

covered). The cardboard undercrawl window mask should be

in place to reduce exposure to the ceiling.

As shown in Figure 10 on page 4, pets are free to roam below

the mounting height of the unit without causing alarms.

Note: Operation of the AP950PI in the Standard Curtain Mode

or in the Bi-Curtain Mode is UL 639 Listed for the pet alley

application at a mounting height of no more than 3.5 feet

(1.1m) with a range of 30 feet (9.1m). For ranges greater than

30 feet (9.1m) or mounting heights higher than 3.5 feet (1.1m),

the unit is not UL 639 Listed.

AP950PI PIR Detector Installation Instructions

3

Advertising