Exiting the program mode, B. using the lcd keypad, C. programming data types – Interlogix NX-1700E User Manual

Page 5: A) numerical data, B) feature selection, Vi. user cards, Action, Important note, Using, Keypad

Advertising
background image

NX-1700E Card Reader

5

E

XITING THE

P

ROGRAM

M

ODE

:

EXIT EXIT

       

Exits this programming level.

B. USING THE LCD KEYPAD

All steps required for programming are the same as the aforementioned LED keypad. The LCD keypad display will prompt you for
the data required. While in the programming mode, and not in a location, the number in parenthesis is the location you were
previously changing. For example, if the display reads "Enter location, then # (5)", it is reminding you that location 5 was the last
location you programmed. In feature selection data, the numbers of the enabled features will be displayed. The features not enabled
will display a hyphen (-).

C. PROGRAMMING DATA TYPES

a)

Numerical Data
Numerical data can take on values from 0-255 or 0-15 depending on the segment size.

b)

Feature Selection
Feature selection data is used to turn features on or off.

VI.

USER CARDS

Adding and de-activating users is done through a combination of entering information at the keypad and scanning cards. Before a
card can be entered, one reader on the system must be programmed with User Card Programming enabled (Location 242, Segment
1, Option 1, page 8).

It is recommended that only one reader on the system be enabled to modify user cards and that this reader

be located near a keypad. This reader will transfer information to all other readers in the system once
programming is finished.


Once a reader is enabled to modify users, it must be placed into one of the following five modes:

1) Add One User
2) Add Multiple Users w/ Auto-Increment
3) Activate One User
4) De-Activate One User
5) Delete/Reset One User.

Modifying users on a card reader is similar to modifying user codes at a keypad.

MUST BE A MASTER USER IN ORDER TO MODIFY USER CARD INFORMATION.

ACTION

RESULT

  

       

Accesses Code Programming

[

master code

]

Factory Default is



       

If the code is valid, the Ready LED will flash.

User Number 2 is used to program user cards, so…

  

if the control is an NX-6, or NX-8

   

if the control is an NX-8E

       

Unit is now ready for you to choose one of the User Card
Programming modes (as if user code 2):

1)

Add One User

2)

Add Multiple Users (w/ Auto-Increment)

3)

Activate Single User

4)

De-activate One User

5)

Delete / Reset One User

IMPORTANT NOTE

Adding or de-activating user cards from a reader will cause the code for User Number 2 to become invalid. Therefore, it will need to be
re-entered after all user cards are programmed into the readers.

Advertising