Segment 2 double scan function {double beep, Segment 3 single scan hold function {triple beep, Segment 3 single scan function {single beep – Interlogix NX-1700E User Manual

Page 8: Segment 4 double scan function {double beep, Segment 5 single scan hold function {triple beep, Segment 1 system options, Location 241, Location 242, Programming the options and reader partition, 240 r

Advertising
background image

NX-1700E Card Reader

8

Segment 2

Double Scan Function {Double Beep}

Program the functions that are performed when a card is scanned twice within the 2 Scan Hold Time {two beeps}. Location 244,
Segment 1 programs the length of time between beeps. The descriptions of the options are the same as for Single Beep Scan
Function. Default is 1.

Segment 3

Single Scan Hold Function {Triple Beep}

Program the functions that are performed when a card is scanned and held at the reader for the duration of the 2 Scan Hold Time
{three beeps}. Location 244, Segment 1 programs the length of time between beeps. The descriptions of the options are the same
as for Single Beep Scan Function. Default is 1.

L

OCATIONS

1

-

240 R

ESERVED

L

OCATION

241 P

ROGRAMMING THE

X-10

A

DDRESS FOR THE

S

CAN

F

UNCTIONS

(5 segments of numerical data)

Segment 1

Program a number from 0 -15 to represent the corresponding X-10 Module Number from the following table.

Default is 0.

Module

1

2 3 4 5 6 7 8 9 10 11 12 13 14 15

16

Seg 1

0

1 2 3 4 5 6 7 8 9 10 11 12 13 14

15


Segment 2

Program a number from 0-15 to represent the corresponding X-10 House code from the following table. Default is

0.

X-10 ADDRESS CODES

0=A

4=E 8=I 12=M

1=B 5=F 9=J 13=N
2=C 6=G 10=K

14=O

3=D 7=H 11=L 15=P

Segment 3

Single Scan Function {Single Beep}

Program the X-10 function that is performed when a card is scanned {one beep}. This location only needs to be programmed if
Location 0, Segment 1, Option 7 is set. Use the following table. Default is 2.

Function #

Function performed

Function #

Function performed

0

All units off

4

Dim

1

All lights on

5

Bright

2 On 6

All lights off

3 Off

All

others

Reserved


Segment 4

Double Scan Function {Double Beep}

Program the X-10 function that is performed when a card is scanned twice within the 2 Scan Hold Time {two beeps}. Location 244,
Segment 1 programs the length of time between beeps. The descriptions of the function codes are the same as for Single Beep
Scan Function. This location only needs to be programmed if Location 0, Segment 2, Option 7 is set. Use the above table. Default is
3.

Segment 5

Single Scan Hold Function {Triple Beep}

Program the X-10 function that is performed when a card is scanned and held at the reader for the duration of the 2 Scan Hold Time
{three beeps}. Location 244, Segment 1 programs the length of time between beeps. The descriptions of the function codes are the
same as for Single Beep Scan Function. This location only needs to be programmed if Loc 0, Seg 3, Option 7 is set. Use the above
table. Default is 2.

L

OCATION

242 P

ROGRAMMING THE

O

PTIONS AND

R

EADER

P

ARTITION

(4 segments of binary data)
Segment 1

System Options:

LED1 -

"On" if reader is enabled for User Card Programming.

LED2 -

"On" if optical tamper is enabled.

LED3 -

"On" if reader buzzer is to follow typical keypad buzzing. (Default is “On”)

LED4 -

"On" if ding-dong chime enabled (dependent on both Option 3 and chime being enabled).

LED5 -

“On” if an RTE from a scanned card is to be logged as Code Entry. (Default is “On”)

LED6 -

“On” if reader is in NX-1700E Legacy Mode (Default is “On”). Refer to note below.

LED7 -

“On” if an RTE) from a zone or the Egress input is to be logged as Code Entry.

LED8 -

“On” if LEDs to extinguish after 2 minutes without a scan. (Note: This option doesn’t disable the flashing green
LED during card programming.)

The card reader is defaulted to the “Legacy mode”. This mode uses the same scan method as previous NX-1700E card

readers. However, an alternative scan method is available by turning off LED6 in Location 242, Segment 1. Rather than
passing the card (scan) within range of the card reader, the card can be held at the reader for a specified number of beeps.
Example of Double Scan: Legacy mode -- Pass the card by the reader’s sensor, remove it from the sensor area, then pass
the card by the reader’s sensor once again. Alternative mode -- Hold the card at the card reader for a total of 2 beeps.
Refer to the Glossary on page 24.

IMPORTANT: If you have older models installed in the system without this enhanced feature, it could result in two
different

methods of scanning at various readers.