Cleaning method, Uninstallation the product – Coway BA08-AR User Manual
Page 26
26
CLEANING METHOD
Uninstallation the product
1 . Unplug the power plug from the outlet .
2 . Close the main water supply valve .
3 . Place a big wash basin (1 L or more) under the rear
drain hole of the bidet .
4 . Turn the drain stopper to
1
counter clockwise by 90 °
and pull out it in the direction of
2
to remove it .
- Please assemble the drain stopper to the product again after
draining.
5 . Please separate the product by removing the fixing
nuts in the fixing screw and lifting the bidet .
- Please pull out the power plug and separate the bidet hose from
T-shaped connector before separating the product.
- When storing the product, separate the filter fixed stopper and MF
filter from the bidet and store them with installation materials.
- Exercise caution not to lose fixing screws and fixing nuts.
When you don’t use the product for a long time, unplug after turning off the main water
supply valve and emptying the water inside the water tank.
Tips