Figure 3 removing an ac-input power supply caution, Step 8, Use two hands to slide power supply out of bay – Cisco 12012 User Manual

Page 9: Ac-input power supply

Advertising
background image

Cisco 12012 Gigabit Switch Router Card Cage Assembly Replacement Instructions 9

Removing and Replacing a Card Cage Assembly

Step 7

Grasp the power supply handle and pull straight out to disconnect the power supply from
the backplane connector. Slide the power supply halfway out of the bay slot. (Refer to
Figure 3.)

Figure 3

Removing an AC-Input Power Supply

Caution

The AC-input power supply weighs 18 lb (8 kg). Use two hands when handling the power

supply.

Step 8

Place your free hand underneath the power supply for support and slide the power supply
completely out of the bay slot. Set the power supply aside

Repeat Step 2 through Step 8 for the rest of the AC-input power supplies.

Note

If there are any power supply blanks installed, remove them by loosening the captive screw

on the power supply blank faceplate. Slide the power supply blank out of the power supply bay slot.
Set the power supply blank aside; you will replace the power supply blank in the replacement card
cage assembly.

AC
OK

OUTPUT

FAIL

INPUT:

200 - 240V

~

10 A
50/60 HZ
2000 W

AC
OK

OUTPUT

FAIL

INPUT:

200 - 240V

~

10 A
50/60 HZ
2000 W

H10376

Use two hands to slide power supply out of bay

AC
OK

OUTPUT

FAIL

INPUT:

200 - 240V

~

10 A
50/60 HZ
2000 W

AC-input
power
supply

Advertising