Troubleshooting Installation Problems

This section contains general troubleshooting information to help you solve problems you might encounter during the
installation of the system. For any problems not covered in this section and for more detailed troubleshooting information, see
the

Cisco 10000 Series Internet Router Troubleshooting Guide

.

General Troubleshooting Tips

All Cisco 10008 field-replaceable units (FRUs) are hot-swappable. Procedures for removing and replacing the FRUs can be
found in the

Cisco 10000 Series Internet Router Troubleshooting Guide

.

Table 4 lists general FRU fault symptoms and recommendations.

Table 4

General Troubleshooting Tips

Symptom

Steps to Take

System fails to power on

Check that:

All power cords are properly connected to the Cisco 10008 router and at the power
connection end.

The PEM power switches are in the On position.

For DC PEMs, the POWER LED should be on (green).

The blower module is fully inserted (FANS OK LED is on [green]).

System fails to boot up properly

If the system has power, check the FAIL LED on the PRE and any information on the
alphanumeric display. If the FAIL LED is on, see the

Cisco 10000 Series Internet Router

Troubleshooting Guide

.

DC PEM problem

If the FAULT LED is on, see the

Cisco 10000 Series Internet Router

Troubleshooting Guide.

If the MISWIRE LED is on, the –48V and return (RTN) wires are reversed. Power
off the PEM and reconnect the wires correctly (see the

“Connecting DC Power to

the Cisco 10008 Router” section on page 19

).

System experiences a critical alarm
(CRITICAL LED on the PRE is on)

Enter the show facility-alarm status command at the console.

System experiences a major alarm
(MAJOR LED on the PRE is on)

Enter the show facility-alarm status command at the console.

System experiences a minor alarm
(MINOR LED on the PRE is on)

Enter the show facility-alarm status command at the console.

You cannot establish a console or
Telnet connection to the system

For information about troubleshooting Ethernet connections, see the

“Troubleshooting

Ethernet Connections” section on page 45

.

For information about troubleshooting the console port serial connections, see the

“Troubleshooting the Console Port Serial Connection” section on page 46

.

Fan failure

If a FAN FAILURE LED lights, perform the following steps:

Reseat the blower module (see the

Cisco 10000 ESR Blower Module Installation

).

Remove the rear safety cover and be sure that the blower module cable is connected
securely (see the

Cisco 10000 ESR Blower Module Installation

).

System overheats

See the

Cisco 10000 Series Internet Router Troubleshooting Guide

for additional

information.