Connect Tech Blue Heat/Net Sync User Manual

Revision 0.03

29

mac=
This displays the MAC address of the unit. (The default is 00:0C:8B:SS:SS:SS,
where SS:SS:SS is the hex value of the serial number of the unit). Note: The
MAC address cannot be changed, it can only be displayed.

dhcp=
This enables or disables DHCP support.
yes

enables

no

disables (default)



NOTES:

All IP addresses are entered in common IP address
notation:

ddd.ddd.ddd.ddd where ddd is a decimal number

from 0 to 255.

IP address “my_ip, server_ip, gateway_ip and dns_ip” can
be entered right justified, meaning that the address
entered will be applied to the specified address starting
from the least significant digit, masked by the subnet
mask. For example:
If the subnet mask is set to

255.255.255.0, and the

following command is entered:
net net=12.23.34.00 mip=45 sip=56 gip=67 dns_ip=89
The following IP addresses result:
the Blue Heat/Net Sync unit will be

12.23.34.45

the Server will be

12.23.34.56

the Gateway will be

12.23.34.67

and the DNS IP will be

12.23.34.89

save

Syntax:

save

Description:

This command saves the setting changes into the CDS in the non-volatile (flash)
memory.

Options:

(none)

update

Syntax:

update <-os | -loader | -jffs> [server_ip= | sip=] [file=]

Description:

Download and store (in flash memory) a new uClinux Operating System image
or a new Loader/SCM image. The download is conducted by a TFTP download
from a Server. After download the image file is checked as being a valid gzip
file (file is decompressed to validate its contents), and then the file is stored in
flash memory. The OS file is stored in flash in its compressed form, but the
Loader is stored uncompressed.


Options:

-os | -loader | -jffs

Use -os to update the uClinux OS.

Use –loader to update the loader/SCM.

Use –jffs to update the JFFS system (Journaling Flash File System).