Connect Tech BLUE HEAT/NET SYNC CTIM-00044 User Manual

Page 60

Advertising
background image

Connect Tech Blue Heat/Net Sync User Manual

60 Revision 0.03

Serial Mode (smode)

BHN_PortSettings

Async

MonoSync

BiSync

Trans-BiSync

HDLC

sync_addr.rx0

Required

Required

Required

Required

sync_addr.rx1

Required

Required

Optional

sync_addr.rx_len

Required

Required

Required

sync_addr.strip_sync

Optional

Optional

Optional

dbits.t/rx

Required

Required

Required

Required

Required

tx_frac_stop

Required

parity.t/rx

Required

crc.tx_type

Required

Required

Required

Required

crc.tx_start

Optional [6]

Optional [6]

Optional [6]

Optional [6]

crc.tx_mode

Optional [6]

Optional [6]

Optional [6]

Optional [6]

crc.rx_type

Optional [6]

Optional [6]

Optional [6]

Optional [6]

crc.tx_start

Optional [6]

Optional [6]

Optional [6]

Optional [6]

tx_trig_gate

Required

Required

rx_gate

Required

Required


Required [1]:

Must be NRZ or NRZ_INV


Optional [1]:

Needed if a clocking source feeds either of the Baud Rate Generators. If the Receiver or Transmitter are clocked directly from certain Line
Interface signals (RxC or TxC setup as inputs) and those Interface signals are setup as outputs, then the indicated parameters are required.

Optional [2]:

Required only when the DPLL is part of the clocking tree setup.

Optional [3]:

Required only when either Counter (CTR-0 or CTR-1) is directly clocking the Receiver, Transmitter, RxC or TxC signals.

Optional [4]:

Only required when the clk_tree.A setting is CLK_DPLL (which is generally only used with Synchronous modes).

Optional [5]:

Only required when the clk_tree.A or clk_tree.C setting selects a Baud Rate generator.

Optional [6]:

Only required if CRC is enabled.