MS-3000 MicroStar Reader

2305 Bering Drive

01815-001 Rev. H

San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: [email protected]

Page 2 of 8

Quick S

tart Guide

MS-3000

1.2

Operating Voltage

5v to 14v DC @ 50 ma

1.3

Cable Specifications

up to 500 feet using six conductor, shielded, stranded AWG 24 wire (such as Belden 9536)

2.0

Mounting Instructions

Three holes need to be drilled to mount the MicroStar Reader (see Figure 1). One large hole (0.875"
- 7/8") accommodates the beeper and the reader cable. Two small holes are for mounting the reader
on the mullion or door frame (hole size is dependent upon the size of the mounting screw).

NOTE: Do not mount the reader near sources of Electromagnetic Interference (EMI) such as a
computer monitor. EMI degrades a reader's read range.

3.0

Connections

The MicroStar Reader does not require configuration; there are no switches or jumpers to set. The
MicroStar Reader is normally connected to a PXL-250, PXL-100, or IntelliProx, but can be
connected to an alternative host controller/alarm panel through an IntelliProx used in its Wiegand
input device mode. All connections needed to support the reader are made through the reader's
cable. Please consult the tables on pages 2 and 3 for specific connection instructions.