2 design 5 pxl-100 connections, Ms-3000 microstar reader, Quick s tart guide ms-3000 – Keri Systems MS-3000 User Manual

Page 4

Advertising
background image

MS-3000 MicroStar Reader

2305 Bering Drive

01815-001 Rev. H

San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: [email protected]

Page 4 of 8

Quick S

tart Guide

MS-3000

3.2

Design 5 PXL-100 Connections

The "A" reader connects to TB2, pins 14 through 19. The "B" reader to TB3, pins 20 through 25.

Connecting the PXL-100 – TB2

Connecting to the PXL-100 – TB3

Figure 3: Design 5 PXL-100 Connections

NOTE: Please contact customer support at Keri Systems for information regarding connecting a
Reader to a Design 4 PXL-100. A Design 4 PXL-100 can be identified by the location of its power
connection made at the middle of the left edge of the printed circuit board.

Pin #

Function

Wire Color

Pin #

Function

Wire Color

14

Green LED

Brown

20

Green LED

Brown

15

Beeper

Green

21

Beeper

Green

16

Reader Power

Red

22

Reader Power

Red

17

Reader Ground

Black

23

Reader Ground

Black

17

Shield

Silver

23

Shield

Silver

18

Reader Antenna

Blue

24

Reader Antenna

Blue

19

Red LED

White

25

Red LED

White

Advertising