11) Specifications and System Requirements

Controller Architecture - Single door networkable access control system

System Configuration - Accomplished with either the TAP-100 DOS based software or the HPP-100

Hand Held Programmer.

System Capacity - Controllers - From 1 to 32 controllers (1 to 64 Doors if using in conjunctions with

an OB-9 2nd Door Control Option Board)

- Cardholders - 7000 cards stored locally at each controller
- Transactions - 3000 events stored locally at each controller
- Time Zones - 32 distinct time zones
- Holidays - 20 Days

Outputs - RS-232 serial port for external communications to PC, modem or printer
- RS-485 network communications when not using the system in stand alone mode
- General purpose inputs and outputs are configurable depending on system setup

Memory Retention - 5 year battery back up of RAM

Power Requirements - 12 VAC @20VA or 12VDC @1.5 Amp

Power Output -12VDC for lock power, 400 mA max, Relay (formerly open collector on design 4 units)

Current Draw - Not to exceed 900mA (including PXL-100, Reader, and Door Strike)
- PXL-100 + Option Board (400mA max)
- MS-3000/MS-5000/KDF-3E/KWS-5E (100mA max), KMI-20E/KME-22E (250mA max)

Relay Contact Rating - 32VAC @ 5Amp max

24VDC @ 2Amp max

Inputs - Door Sense

- Normally Closed

- REX

- Normally Open

- Gen Purpose

- Normally Closed

Printer Requirements - Serial RS-232

2400 BAUD
8 Bit , no parity
1 stop bit

PC Requirements - IBM Compatible, 386 or better, Color monitor, 20 megabyte hard drive and 1
Mbyte of RAM and 520KB free of conventional memory. Keri recommends
installing and running the software from the hard drive.

12) Cable and Wiring Requirements

Cable Requirements for Readers - Readers (Belden 9536, 22AWG or equivalent. Larger guages

should be used for longer distances.)

Reader Type

Length with 24AWG

Length with 22 AWG

KDF-3E, KWS-5E

450'

600'

MS-3000, MS-5000

350'

500'

KSI-10E, KSE-12E

350'

500'

KMI-20E, KME-22E

300'

450'

Advertising