Pxl-100: smart entry controller, 1) warnings, 2) pxl-100 diagram – Keri Systems PXL-100 User Manual

Page 2

Advertising
background image

Page 2

01816-100 Rev. E

1530 Old Oakland Rd., Ste 100 San Jose, CA 95112 U.S.A. (800)260-5265 (408)451-2520 Fax (408)441-0309

PXL-100: SMART ENTRY CONTROLLER

.

1) Warnings

This document should only be used for the design 5 board or later versions. To identify a
design 5 board, look for the two relays in the center of the PC board. If there are two next to
each other, it is a design 5 board.

When disconnecting or reconfiguring any PXL-100 or peripheral products, ensure that the
power has been disconnected. Serious damage such as RAM failure may occur if an option
board or other peripheral product is disconnected while power is on.

2) PXL-100 Diagram

GND
NC
GND
REX (RTE)
GND
NC

(Jumper
Selectable)

NO
COMMON
NC

EARTH
GND
+12 VDC
12 VAC
12 VAC

GRN LED
BEEP
+12 VDC
GND
RDR
RED LED

Firmware

Battery
3 V Lithium
#BR2325

External Time Zone

Exit Button or PIR

Magnetic Door Switch

12 VDC

Alarm Device

12 VDC Out

Gnd
Relay
Relay
Relay

To Door Lock or Parking Gate

To B Proximity Reader

Green
Red
Black
Blue

Door Lock
Relay

Alarm Out
Relay

(new for design 5)

GRN LED
BEEP
+12 VDC
GND
RDR
RED LED

To Primary Proximity Reader

Green
Red
Black
Blue

JP6 J4

JP3

3) Features and Functions of the PXL-100 Smart Entry Controller

The PXL-100 can be used as a stand alone unit or function as a networkable access control system
capable of controlling up to sixty-four doors (with the addition of an option board). Standard features
include:

- a database capacity of 7000 unique users per controller
- transaction buffers capable of storing 3000 events per controller
- expansion port for adding special feature option boards
- built in power supply that can run off 12VDC or 12VAC and can power door strikes
or magnetic locks
- RS-232 serial port configurable to communicate with a PC or printer
- an optional RS-485 network communication capable of linking up to 32 controllers
on a single network
- I/O including door status, request to exit, two 10Amp Form-C relay for door strikes
and alarm shunting.

Advertising