LC-502P/LC-508P

5.1

Connecting Wires - Removing Terminal Blocks

Follow the instructions in Figure 5 when connecting wires to the controller or when removing
terminal blocks from the controller.

Figure 5: Connecting Wires and Removing Terminal Blocks

5.2

LC-502P Wiring Connections

The following connections are made to install the LC-502P Elevator Control panel (see Figure 3 on
page 8).

Floor Control Relay

RS-485 Controller Network

Reader Daisy-Chain

Earth Ground and Power

5.2.1

Floor Control Relay

The Floor Control Relay is connected to the floor controls at the elevator panel. If a controller has
an SB-500 Satellite Board attached to control two floors, connect the lower floor to the A-Floor
Control Relay and connect the higher floor to the B-Floor Control Relay. Make the floor control
relay connections per the information in Table 2 and Figure 6 on page 11.

Table 2: Floor Control Relay

Connection

LC-500P TB-3 Pin

SB-500 TB-7 Pin

Description

1

Normally-Open

2

Common

3

Normally-Closed