Proximity elevator control panel – Keri Systems LC-508 Proximity Elevator Control User Manual

Page 21

Advertising
background image

Proximity Elevator Control Panel

2305 Bering Drive

01941-001 Rev. B

San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: [email protected]

Page 21 of 22

LC-502P/LC-508P

Quick S

tart Guide

3. Daisy-chain the TxRx+, TxRx-, and Shield Network Communication connections from the

terminal strip on the first panel to the terminal strip on the second panel. Make the connections
per the information in Table 8 and Figure 14.

Figure 14: LC-508P to LC-508P Nework Communication Wiring

4. The floor/relay connections for the second LC-508P are made according to the floor/panel

association. Refer to Section 5.3 on page 15 for all floor/relay connections to the LC-508P.
Power connections are made per the instructions in Section 5.2.4 on page 15.

Table 8: LC-508P to LC-508P Nework Communication

Wiring

TB-B on First LC-508P

TB-C on Second LC-508P

TxRx-

TxRx-

TxRx+

TxRx+

Shield

Shield