or combustion air terminal terminate through a wall,

and there is potential for snow accumulation in the local

area, both terminals should be installed at an appropriate

level above grade.

The dimensions and requirements that are shown in

Table 1

should be met when choosing the locations for

the appliance.

1.6 Locating Pump-Mounted Water Heater

with Respect to Storage Tank(s)

For best results, a pump-mounted Mighty Therm2

water heater should be located within 15 feet (4.6m) of

the storage tank(s). The pump is sized for 30 feet (9.1m)

of piping.

If the appliance must be installed with longer

piping runs, then larger diameter pipe or tubing shall be

used. Consult the factory for assistance.

Figure 1. Dimensional Data (standard units).

Air

Vent

Shipping Weight

1

Unit

Conn.

Conn.

Size

A

B

C

D

E

W

V

lbs

kg

500

33¾ 85

16¾ 43

17

10 25

8 20

6 15

8 20

425 193

750

45¾ 116

22¾ 53

17

10 25

24

6 15

10 25

505 229

1000

57¾ 147

28¾ 73

17

10 25

24

8 20

10 25

615 279

1250

68¼ 173

34

87

10¼

26

10 25

9 23

8 20

12 30

675 306

1500

78¾ 200

39½ 100

10¼

26

10 25

9 23

8 20

12 30

760 345

1750

89¼ 227

44¾ 113

10¼

26

10 25

9 23

8 20

14 36

825 375

2000

99¾ 253

49¾ 127

10¼

26

10 25

9 23

12 30

14 36

955 434

NOTES: 1. Add 55 lbs (25kg) for pump-mounted units.

Dimensions in inches cm.